We Have a 2005 Norcold side by side model 1200 Refrigerator and installed the JC Refrigeration 12 volt DC system on November 7, 2019.  We are full time and have been using the refrigerator since then.  Today we left for the day and when we came back the refrigerator was off and had been for quite some time.
The front panel showed it was on.
I checked all fuses, connections, etc and it is fine.  There is 12 volt power to the Norcold board and when it tries to start the compressor there is 12.6 volts there.
The house and engine start batteries are at 13.4 volts with the charger on.
To rule out the Norcold control board I bypassed it and put the 12 volt power directly to the compressor’s controller.  Once powered the compressor makes a buzzing noise but not sure if it is running properly.  I will leave it powered up for a few hours to see if it cools the refrigerator.  If not I will unplug it and call for help in the morning.

We connected to the existing 12 volt wiring which is 10 gauge so there is no voltage drop occurring.

The Norcold board and front panel were replaced last September by an RV technician in Florida.  

Since install (Nov 7) the system has been working extremely well.  It was on last night and this morning before we left for the day.  We have a progressive industries surge / power protector installed so we do not suspect anything happened there.

What other diagnostics can we run to identify the problem.  At this point we believe it is either the Norcold Control Board, the Compressor controller or the compressor.  Or all the above.




Reply 0 0
Jr Lambright
thanks for reaching out to us, you are on the right track, couple things to mention or make sure of, make sure the fin fan is still running inside the fridge, and make sure the compressor fan has power to it and that it comes on which is a sign that the compressor is running. so wiring the compressor direct is the proper way to diagnose or back track to see what is not functioning. once wired direct it should start to cool again within a hour and overnight in this heat even with food inside the fridge should be down to where it needs to be. so keep me in the loop what you have this morning
Reply 0 0
Svsheric
Hello,

Yes I sent a few emails and also posted on the forum.

We have a thermometer that gives us a relative temp with a sensor in the freezer and one in the refrigerator. Since install on Nov 7 the temp is usually zero in the freezer and 34 in the refrigerator. This is at the setting of “1” on the Norcold panel

At 8:30 pm mountain yesterday I wired the compressor direct, bypassing the Norcold board. As of this writing (7 am mountain time) the temp is 21 in the freezer and 43 in the refrigerator with all food removed. Bypassing the board does not provide power to the cooling fin fan nor the fan above the compressor.

The compressor is hot to the touch and is making a humming sound.

I am trying to locate a replacement board at this time but am concerned the compressor’s controller may be part of the problem. We had a similar issue with a refrigeration unit on our boat and a new controller solved the problem.

It may take several days to get a board delivered. How can we manage the hard wired system in the mean time- it will be running 24/7?

Thank you for the quick reply, we are in a bit of a panic mode with lots of food that can spoil and no local help available.

Ric Bischoff
Reply 0 0
Svsheric
Hello,

Upon further inspection of the Norcold control board I found the one end of the fuse holder burned. See attached photo.

In the documentation we received to wire the board to accommodate your cooling system it is noted to change the fuse with the one provided, which we did. Please note the fuse currently installed is intact, it did not fail.

I have ordered a new board and will hopefully have it by Thursday.

*I am very concerned that the board is damaged but the fuse intact.
Clearly the fuse did not do it’s job to protect the circuit or the board.
Is the fuse too high of a rating? Could this have damaged the controller and/or compressor?*

This can be a potential fire hazard if it happens again.

The unit is cooling down the freezer and refrigerator but with it hardwired it will run continuously with no interior or exterior fans operational.

I can, if you agree provide power to the board to permit the fans to run but leave the controller hard wired; receiving no power from the board.

I am also talking to “the Norcold guy.com” about the possibility of getting a different board and control panel that utilizes 12 volt only. Our existing one tries to use propane first then looks for 120 volt ac. I think we are tricking the system to run on 12 volts which may be part of why the board failed.

I look forward to your reply

Sincerely

Richard and Sherry Bischoff
Reply 0 0
Svsheric
This is the photo your company provided during installation. Note where it says to “change fuse to the one provided“.

[IMG_1163]

[A6EB025F-BBD0-448E-A583-43E20EF411E9]

Reply 0 0
Svsheric

UPDATE:
Using a buss bar I provided power to the board and the controller on the compressor.  Unfortunately this did not work - no power to front panel on the Norcold.  I suspect the board needs to be connected to the controller for it to work.  

The freezer is at 19 degrees and refrigerator is 47 degrees.   This seems to have reached its lowest level perhaps in part due to the fan above the compressor not running or the one on the interior cooling fans.

A new board should arrive on Thursday and we hope that solves the problem.  For the Bussman type fuse what amperage should it be?


Reply 0 0
Svsheric

The system has reach a stable point of 19 degrees in the freezer and 45 in the refrigerator.  We put food back in that has thawed and warmed which brought the temps up to 21 and 47.
I have the 12 volt power source plugged directly into the controller, no power to the Norcold board so no power to the internal or external fan.

With the compressor running continuously the temps should have much colder in both boxes right?


 

Reply 0 0
Jr Lambright
i see a burn mark on your board which is a sure sign of being burned, but the fridge not getting cold is largely because of the fans not being on, is there a way you could even just get power to the compressor fan for now. without this fan it will cool some but it will not get even close to where you want to be, so once you have the board changed you should be good but for now i would at least supply 12V power to the compressor fan and also interior fan if possible
Reply 0 0
Svsheric
Thanks for the reply. I will try to get power to both fans until the board arrives.

What size Bussman fuse should be on the Norcold board?
Reply 0 0
Jr Lambright
the glass fuse you want to use on the board for the compressor needs to be a 15A fuse
Reply 0 0
Svsheric
Update:
I powered the fan located above the compressor. Several minutes later the compressor stopped running and the temps began rising.

I had to unplug the fan and am running only the compressor at this time.

There is 12.6 volts at the power connection to the compressor.

I do not understand why the compressor would stop with the fan running.
Could this be a controller issue?
Reply 0 0
Jr Lambright
the fan needs to be run off your coach 12V, where is the fan getting its 12V power ?
Reply 0 0
Svsheric

Update:  We received and installed the new Norcold control board today.   The system appears to be working properly and is cooling down.

I am looking into why the original board failed.  It could have been due to corrosion on the Bussman fuse holder causing more resistance and therefore excessive heat.  More investigation is needed here as hope to find the root cause to prevent it from happening again. 

Even though the 12 volt wire run to the refrigerator is sufficient size we are running A dedicated. 8 gauge wire directly from the house Battery bank with an in-line fuse installed.  This will rule out any power related issues.

Thank you for your support in this matter
 

 

Reply 0 0
Jr Lambright
let me know what you find in your research on the board, the compressor will put a 7.5DC A pull on the board while the heaters before had a 4A AC which would be equal to 40A DC, so i would tend to think the compressor would create a better scenario for the board, moisture is the killer for these boards, rain while traveling or car washes etc. not something to be concerned about but just a thought 
Reply 0 0
Svsheric
Since replacing the defective Norcold board the refrigerator has been working well.  I suspect the Bussman fuse holder had some corrosion which created excessive resistance that damaged the board.  I will keep an eye on the new board to see if this problem returns.
We follow several RV Facebook pages And always recommend your product when people ask about replacing or fixing their refrigerators.
On another note Our unit is 12 volt only.  Can this be changed, upgraded or adapted to run on 120 volt ac as well?  Not sure if I want to do this but would like to know if it is possible.