Kxbronco
My unit was just shipped today, but I’m beginning the prep for installing it. I will be removing a Norcold 6052 and replacing it with the Dometic 2862. They’re basically the same dimensions except for the height. I know the Norcold doesn’t have any insulation on one side, but don’t know about the other.  Since I’m converting to a 12v HAVC, do I need to have insulation of some type on both sides and anywhere else?
Reply 0 0
Kxbronco

I’m not finding a place that I can mount the control board on the new cooling unit frame, but I will keep trying. Once I get into the actual installation I will see what length wires I have to work with.  Just to be on the safe side, I want to have a plan B for mounting the control board.  I can use some extra strength velcro and stick it to the back of the fridge or I can use the self taping screws (maybe some shorter ones) and attach to the back of the fridge. Which would be best?

I plan to start pulling my current fridge out tomorrow. I will have to make some tweaks to the cabinet to accommodate the taller fridge I’m putting in.  If things go well I will put the new fridge/cooling unit in tomorrow afternoon or Tuesday. 

Reply 0 0
Kxbronco

After watching video #4 about the 3-way splitter wiring, I got to looking at the wiring on the back of my fridge, the wiring on the new cooling unit and the wiring instructions for my control board. I’ve got more questions (surprise surprise). 

1) For the light in my fridge, there is a red and a black wire. The instructions show where the red wire goes to the control board, but it doesn’t show where the black wire goes. If I remember correctly the black wire has a loop connector on it. Where am I supposed to connect the black wire?


2) there is a black wire with a connector (female I think) coming from the fan over the compressor. Is it supposed to be connected somewhere?  If so, where?

Reply 0 0
Jr Lambright
#1 the black light wire is ground, so just put a ground eyelet on it and screw to to the control plate
#2 the compressor fan needs to be red to plus and then black to ground, which again you just put a ground eyelet on it an screw it to ground
Reply 0 0
Kxbronco
Kxbronco wrote:

I’m not finding a place that I can mount the control board on the new cooling unit frame, but I will keep trying. Once I get into the actual installation I will see what length wires I have to work with.  Just to be on the safe side, I want to have a plan B for mounting the control board.  I can use some extra strength velcro and stick it to the back of the fridge or I can use the self taping screws (maybe some shorter ones) and attach to the back of the fridge. Which would be best?

Hey Jr,  I think the question above got missed. I made two posts over a couple of days so I got things a little out of sequence. If you can give me some input on it.

#1 the black light wire is ground, so just put a ground eyelet on it and screw to to the control plate
#2 the compressor fan needs to be red to plus and then black to ground, which again you just put a ground eyelet on it an screw it to ground

For clarity’s sake, when you say “control plate” are you referring to the tan colored metal frame that holds the cooling unit together?

On the fan wiring, you say “red to plus”.  The red wire is already connected to the black thing in the copper tubing (see pic below). I assume this is as it should be and doesn’t need to be moved, correct?  And the black fan wire (seen in pic below hanging from coils) has a female connector on it.  Your saying cut it off and put on a loop connector and attach at the same place as the light ground, correct?

18901896-3D60-4D60-BA19-B95FF916A6D7.jpeg 

Reply 0 0
Jeremy Lambright Jeremy Lambright
Annotation 2020-09-02 153632.png        Attach control board to this section on picture with self taping screws. 

                                                 Both of your above questions are correct. Take black fan wire and black light wire and ground to aluminum control plate or the compressor plate. 
Reply 0 0
Kxbronco


  Both of your above questions are correct. Take black fan wire and black light wire and ground to aluminum control plate or the compressor plate. 


Thanks for the reply Jeremy.  It was good talking to you today.  I just don’t have the vocabulary. When you say “aluminum control plate or compressor plate”, is the aluminum plate the metal the fan is mounted too?  Is the compressor plate the metal the compressor is mounted too?

So I got the cooling unit mounted into the fridge. Went super smooth!  Used all of the thermalmastic. I used all of the foam. That may have been a huge mistake. Never used that kind of foam before. I applied the foam after the unit was installed and basically filled the gaps full Around the unit. Had foam bubbling up everywhere. I can trim it back before I tape it.  My concern is that some of the foam came out on the inside around the fins. I can trim it off. Is the foam coming out around the fins going to be a problem?

Reply 0 0
Kxbronco

As it pertains to the foam coming out around the fins inside the fridge, I talked to Jeremy this morning and since I mounted the fins to the cooling unit prior to installing the cooling unit, I should be ok. Jeremy was a bit concerned about the foam getting in between the plates (where the thermal mastic goes), but when I told him I mounted the fins prior to installation he said I was ok. He told me just to remove the foam around the fins as best I could. All the fins are clear with just a small film from where the foam was stuck. 

The unit is installed and running fine. Still need to put the fans on the fins. Freezer and fridge are cooling down really good.  Couple of questions now about the operation:


1) The compressor is too hot to touch. I think this is normal, but want to confirm with you?

2) The cold line from the compressor is really sweating and dripping.  Again, I think this is normal given the heat and humidity, but want to confirm with you?  If normal and to be expected, do I need to put something under the cold line to catch the water?

8E82BBFE-B8D6-49DE-8C5B-DC52F959A0BF.jpeg 

Reply 0 0
Kxbronco

Jeremy/Jr - See previous post for a couple of operational questions

Fridge temps update. After about 5 hours, the freezer is at ~5 degrees and the fridge is at ~50 degrees. Fridge is set on coldest setting and the thermistor is in the middle of the right most fin. 


Also just noticed that my inside fridge light isn’t working. Tried changing bulbs, but that wasn’t it. Light was working prior to installation.  Trying to figure that out.

Will be taking the moho back to storage later today. May be next week before I can work with it again. 

Reply 0 0
Jr Lambright
the sweating will go away as the unit starts to cycle and its more stable, right now its running full time and some moisture might accumulate, and yes the compressor will run from 145F to 200F and that's very normal. the freezer being -5 and the fridge at 50F, is the fin fan been attached now and running? and the light very likely does not have 12V to it and if that's the case then the fin fan is probably not on either and that would explain the warm fridge
Reply 0 0
Kxbronco
Thanks for the confirmation info Jr. The fin fan is not attached yet. Was going to put it on, but then I found out the light wasn’t working. Trying to figure that part out now. May be next week before I get to look at it again. 
Reply 0 0
Kxbronco

Jr/Jeremy,  I think I know the problem with the light.  I’m not getting 12v at the light connection on the board.  I’m not an electrical guru, but I’m pretty sure it’s a ground problem. In the pic below (needs to be rotated to the right) you can see where I have the light and the compressor fan grounds screwed down to the panel. If I test the voltage using the light circuit on the board and the screw I’m only reading 1v max. If I do the same test but use the ground coming directly from the moho or where the 3-way splitter attaches to the ground circuit on the board, I get ~12.5v. 

You can also see where I have the fridge board mounted on the back of the fridge. It’s held on with velcro.  I tried scratching some of the paint off the panel where the grounds are attached, but that didn’t work.  With my limited knowledge, I don’t see how the panel can act as a ground.  Can y’all give me some suggestions as to how to resolve this issue?

2C961D7B-87B3-409E-B453-85874D613ED8.jpeg 
 

Reply 0 0
Jr Lambright
yes in this scenario you will have to put a split connector on the ground going to the board thru the 3 way splitter, and fasten that to the wires you have going to the compressor plate now, normally we leave the metal plate the board is on in place then screw that to the compressor plate which will then ground that out, but doing it this way will work to, you just want to connect all those grounds together
Reply 0 0
Kxbronco
Thanks Jr.  That’s what I was thinking. 
Reply 0 0
Kxbronco
I got my ground issue corrected today and the inside light and fans are now working as expected. Of course I have a couple more questions:

1) I have the fridge running and there is a lot of vibration. So much so that you can feel it and hear it inside the moho. What can I do to reduce the vibration?

2) The fans are currently running. Once the fridge cools down, when should I be running the fans and for how long?
Reply 0 0
Jr Lambright
#1 a thumping vibration is normally a low voltage issue, how bad is it? because on some of those 2852s the main frame does not go under the fridge like others do and so its hard to get a good solid connection between unit and box and so at times there is the harmonics of the compressor that will make this humming rattling sound, and all it takes is to put your hand on it and it quiets down and so if that i s what it is you might want to shim the compressor frame a tad or see if you can make it more rigid to the box to stop it from humming.
#2 the compressor fan just needs to run when the compressor comes on while the inside fan needs to run all the time, they take less then 1/4 A so its very little power usage and they work wonders to keep the fridge evenly cooled and the frost off the fin
Reply 0 0
Reply